Release history, newest first.
View earliest release ↓Latest documented release
Version 7.0.2.45
Release date: 8/24/2022
Features Added
- API653 allows Joint Efficiency override on riveted tank shell. If the value is zero, defaults will be applied, otherwise the default table values will be used.
- Added Daylight check-box to brighten AScope (suggested by Guy Thigpen) to Utilities | Settings | DisplaySettings Group.
- Hid and disabled operations that are not pertinent on floating gate in Advanced Gate Settings Dialog
- TK Files flag to export two types
- Added [Recover Workable UT and Gate Settings] button to Utilities | Special Tab
- Auto disable/enable IF Gate when changing between Dual/Single transducer setting.
- Brought PreviewLib version up to the same as AnalystXR
- Added button to report settings to reset "Report As" default values
Fixes
- disabled copy, paste pop-up on request of Alan to prevent sync problems with raw files
- minor changes to Thickness chart in wedge cal
- mods to SaveFileSet and RestoreFileSet to prevent missing files if user selects to not save changes on re-scan
- Fixed last HAL segment covering prior segment depending on variables.
- Fixed rounding of Flag value
- Fixed missing HAL when reporting D2S data
- Fixed BScan not visible if D2S and Show AmpBS is checked on Analysis page.
- Fixed bug where original BScan may not match AScans after adding to existing data and not saving changes at the end.
- Fixed bug where original BScan may not match AScans after replacing data a second time and not saving changes at the end.
Version 7.0.2.35
Release date: 8/12/2020
Fixes
- Update caption of Incomplete scans form to match selection.
- Fixed Out of Memory error when re-gating while zoomed. (obscure LiveABS control redraw)
Version 7.0.2.33
Release date: 5/4/2020
Features Added
- Added ability to import Acquist data
- Added Tree/List view button on Analysis tab to prevent user from having to jump back to General tab when analyzing.
- Added ability to save/load previous calibration
- Set scaled property to False on most forms to prevent problems with windows scaling feature.
- Added position feedback in UTCal tab
- Added ability to re-scan without overwriting A-Scan data. (Start, pause, re-position, restart will add to scan.
- Made Amplitude B-Scan spectral palette and made it the default.
- Added INI switch for gray scale Amplitude B-Scan default. ([Display] Spectral=0)
- Added release notes link (bottom right) so we can better communicate added features and fixes.
- Added feedback for Object / ScanPlan / Scan to Perform Scan Page (customer request)
- Added Gain Scaling capability (Advanced Gate Settings)
- Floating Gate capability added
- Added ability to lock position (delete key) while re-gating
Fixes
- Changes to fix timed disconnect tendency when commanding calibration from Perform Scan tab
- Added Amplitude B-Scan
- Added output for incomplete HAL (High, Average, Low) segment if uneven.
- Fixed small bugs in re-sizing GraphiCal control
- Re-enable calibrate button after cal closed
- Fixed notes not showing on report for D2S scans -
Version 7.0.2.16
Release date: 11 26/2018
Features Added
- Separated D2S A-Scans in time to reduce pulser load
- Added thickness to CSV Export
- Added check box to not ask again about Wedge Cal warning
- Added button to skip calibration to verify
- Put constraints on gate adjustments that might not be reasonable
- Added export for TK files
- Added TriggerType persistence
Fixes
- Trapped CSV export to prevent attempts to open file that might not exist
- Fixed CSV export where missing scan would result in improper column alignment
- Fixed List Index out of bounds error when calibrating encoder on D2S scan (rare)
- Assured some gate settings for gate 2 on D2S.
- Fix potential timing problem with Reconnect timer and reset
- Forced IFComp = 0 for D2S Calibration