Version 2.0.1.100

Release date: 5/23/2022
LATEST DOCUMENTED RELEASE

Features Added

  • Refined Report 'Save as' to mitigate possible usage error.

  • Changed anti-aliasing algorithm to mitigate blurry image at the expense of smoothing.

  • Changed Daylight mode to add fill for better visibility

  • Force changes to Colormap before re-gate to assure they are not lost.

  • Added Crop to C-Scan

  • Added labels to avoid confusion on dimensions and functions.

  • Added Measure mode description on A-Scan

  • Added Graphic pipe setup (SIS suggestion)

  • Changed ReportLayout control so that you can move an object without a second click.

  • Added index to Status line for F4 and alt-F4 indicating min point index.

  • When re-gating single point in grid, return cursor to that point when done.

  • Facilitate negative gate on RF waveform.

  • Added another Min arrow on 3D rendering opposite the usual side to help visualize.

Fixes

  • Fixed visibility of lblHealWarning

  • Fixed visibility of Laser specific settings when no scan added.

  • Update Settings panel when AScope changes mod to and from E2E mode.

  • Fixed logic reversal in ReplaceMissingCSImage method

  • Fixed minor bug in colormap if right-click or double-click on adjustment point adjusting flag wasn’t getting reset.

  • Fixed selection (re-gate) on rotated layout

  • Fixed Fit Width flag stuck after using in view scan

  • Fix thumbnail scaling on rotated layout

  • Fixed flag (fShouldReConnect) on perform scan: was not enabled preventing re-connect attempts

  • Fix re-name function Failure to rename Tandam Scan File.

  • Fixed rare bug that filled CScan data blank on view scan tab when UT settings are different that scan and switching tabs in a particular order.

  • Fixed Stitched scan image scale issue.

Version 2.0.1.97

Release date: 12/14/2021

Features Added

  • Ctrl End key combination now works in View Scan mode

  • Changed green in Coast Guard four color palette to 65280 on request

Version 2.0.1.95

Release date: 11/29/2021

Features Added

  • Changed width of help panel when closed so as to prevent interference with other controls on lower resolution displays

  • Changed sleep(1) to sleep(100) between stc requests for speeds

  • Changed CSC background to light gray

Fixes

  • Persist floating gate setting beyond session

Version 2.0.1.94

Release date: 11/1/2021

Features Added

  • Added Coating Compensation in Scan Map settings to subtract Coating thickness from gated thickness readings.

  • Added images tab to Analysis (similar to scan) for Stitched ScanMap Images

  • Added Alt F3 function to save image rendered at custom pixels per bin

  • Added Notes Page to Scan

  • Added Notes variable to Report

  • Added Conditions/Results Page to facilitate customization of results by selection

  • Added Velocity override capability to Condiditions/Results to facilitate measurements between gates on bonded surfaces of different velocity.

  • Added IFComp to UT Settings Panel.

Fixes

  • Fixed dates on last two release notes where year was transposed (12 instead of 21)

Version 2.0.1.93

Release date: 7/30/2021

Features Added

  • Added Daylight check-box to brighten AScope (suggested by Guy Thigpen)

  • Hid and disabled operations that are not pertinent on floating gate in Advanced Gate Settings Dialog

  • Added tandem ut (Gladd)

  • Added CoastGuard 4 color palette (Gladd)

  • Added Jog control in Perform Scan Dialog (Gladd)

  • Added interface to STC controller

  • Added Velocity and Acceleration settings for STC controller

  • Added error handling to pause scan for scan recovery using STC controller

    • E-Stop

    • Motion

    • OverCurrent

  • Added Color Map dialog by double clicking on color map control.

Fixes

  • Fixed object order where buttons were showing through help panel (Chuck)

  • Fixed hidden Template list if Adding scan, selecting Blank and back on Template

  • Fixed selected Re-gate region missing two cells on the right

  • Fixed UTSettings panel not updating when changes made in AScope

Version 2.0.1.91

Release date: 6/7/2021

This release has so many new features that we decided to post a video overview.

Features Added

  • Added hints over check boxes relating to Heal Data features

  • Added layout tab in utilities

  • Added LayoutSimulation object to manage placement based on settings in record

  • Added capability to select desired layout from combo-box in view and perform

  • Added ability for grid to rotate with CScan

  • Added ability for CScan to rotate

  • Added UT settings panel in UT Setup/Calibrate with advanced settings (requiring PRD update)

  • Modified Amplitude B-Scan palette per user feedback

  • GraphicCal: changed location and description of Clear Dataset button (to avoid confusion) — GraphicCal: Automatically clear and set focus on Edit box (per user feedback)

Fixes

  • Clear Dataset button fixed - variables initialized so that chart resets after ban entry.

  • Fixed images compiled into report that have been rotated by property in layout by saving a copy of the image with -Rotated.ext to use in the compiled report

Version 2.0.1.78

Release date: 3/3/2020

No feature or fix details were provided for this release in the original file.

Version 2.0.1.77

Release date: 2/17/2020

Features Added

  • Added release notes link (bottom right) so we can better communicate added features and fixes.

  • Added Please Wait form while loading large A-Scan Array to inform user better.

  • Added Amplitude B-Scan (horizontal and vertical) in C-Scan control

  • Added ability to use spectrum color instead of gray scale Alt=F6

  • Added feed-back on C-Scan control of re-gate region being operated on.

  • Added ability to lock/unlock cross-hairs on C-Scan control so that a user does not inadvertently load gates from another bin by sweeping over the control. (del key)

  • Added Image of area to statistics dialog

  • Added export to excel to statistics dialog

  • Updated StiSceneViewer (V 1.0.0.7)to match AnalystXR (Filter vertex drawing when in transition to zero reading to prevent average facet color to be RED)

  • Trapped Carriage Width error message from SBC and show warning dialog for clarity.

  • Added ability to Heal data if possible. Requires 3 gate setup echo to echo. When gate 2 is not broken the algorithm attempts to use interface to G1 TOF modified statistically for delta between G1-G2 TOF and IF-G1 TOF. This will help fill in some data when echo to echo is required but signal return is difficult to achieve.

Fixes

  • Attempt to solve ghost image due to timing of windows affects when saving named image

  • Fixed rare issue when pasting selected color-map settings; C-Scan image would be duplicated

  • Fixed run-time format error while exporting csv in scan map dimension mode.

Release Notes

Release date: 10/23/2018

Fixes

  • Changed scaled setting on most forms to FALSE to help when windows uses scaling

  • Fixed translation of scan map when orientation is -1 (90 deg left)

  • Placement of [Change Colormap] button on 3D view page

Version 2/0/1/65

Release date: 7/18/2019

Features Added

  • Added ability to save/load a UT Template for calibration and settings

Version 2.0.1.63

Release date: 6/13/2019

Features Added

  • Added ability to export 3D to STL file

  • Ability to scale gain of A-Scan on re-gate (under Advanced Gate Settings Dialog)

  • Added tri-color palette capability

  • Added ability to copy and paste page in reporting

  • Added "Missing Scan" page and notice of no selection available from existing scan set

  • Added highlighting of pressure below burst for each method in B32G output

  • Added ECScanFile (.ECSF) in set for enhanced gating functions at bin level

  • Added Floating Gate capability

  • Added Amplitude B-Scan in array so that a live display is functional as the crosshairs are moved.

  • Added MergeScans for and function to facilitate the merging of two scans that should otherwise occupy the same envelope with the same settings.

Fixes

  • TriggerType persistence

  • Added condition traps in B31G analysis

  • Fixed minor bug in CommandQueue where Index out of bounds due to fChannel > 0 (this would not happen in normal operation).

  • Filter vertex drawing when in transition to zero reading to prevent average facet color to be RED.

  • Changed mode back to MonitorStream mode after re-gate is complete

  • Small fix for Amplitude B-Scan grayscale Zero value rolling over to black

Version 2.0.1.49

Release date: 7/17/2018

Fixes

  • Fixed but reported from field when using Add Blank Scan causes unresponsive perform scan!

Version 2.0.1.48

Release date: 5/11/2018

Features Added

  • Shortened Live Amplitude B-Scan display to Range instead of Record Length.

Fixes

  • Fixed potential timing problem with tmrReconnect when reset is done. (Unlikely)

Version 2.0.1.46

Release date: 5/1/2018

Fixes

  • Added filter in commands going to Single board computer to prevent corruption of platform.conf file if user fails to select scanner type on touch screen.

  • Apply constraints on AScope gate adjustment to assure values are reasonable.

  • Removed debug ShowMessage that was unintended

  • Fix for report element "line" not responding to drag and drop properly.

Version 2.0.1.42

Release date: 2/27/2018

Features Added

  • Added new Special Functions tab under Utility tab with button [Recover workable UT and Gate Settings]

  • Added live aplitude B-Scan display (optional with check box) while performing scan

  • Added Manual

Fixes

  • Added an event to facilitate proper field validation while changing units

  • Trap range settings and frequency settings that are invalid

  • Fix for metric C-Scan Scale

  • Fixed small memory leak with fds.free (missing)

  • Added test for empty scan set when leaving General page