Version 2.0.1.100
Features Added
-
Refined Report 'Save as' to mitigate possible usage error.
-
Changed anti-aliasing algorithm to mitigate blurry image at the expense of smoothing.
-
Changed Daylight mode to add fill for better visibility
-
Force changes to Colormap before re-gate to assure they are not lost.
-
Added Crop to C-Scan
-
Added labels to avoid confusion on dimensions and functions.
-
Added Measure mode description on A-Scan
-
Added Graphic pipe setup (SIS suggestion)
-
Changed ReportLayout control so that you can move an object without a second click.
-
Added index to Status line for F4 and alt-F4 indicating min point index.
-
When re-gating single point in grid, return cursor to that point when done.
-
Facilitate negative gate on RF waveform.
-
Added another Min arrow on 3D rendering opposite the usual side to help visualize.
Fixes
-
Fixed visibility of lblHealWarning
-
Fixed visibility of Laser specific settings when no scan added.
-
Update Settings panel when AScope changes mod to and from E2E mode.
-
Fixed logic reversal in ReplaceMissingCSImage method
-
Fixed minor bug in colormap if right-click or double-click on adjustment point adjusting flag wasn’t getting reset.
-
Fixed selection (re-gate) on rotated layout
-
Fixed Fit Width flag stuck after using in view scan
-
Fix thumbnail scaling on rotated layout
-
Fixed flag (fShouldReConnect) on perform scan: was not enabled preventing re-connect attempts
-
Fix re-name function Failure to rename Tandam Scan File.
-
Fixed rare bug that filled CScan data blank on view scan tab when UT settings are different that scan and switching tabs in a particular order.
-
Fixed Stitched scan image scale issue.
Version 2.0.1.97
Features Added
-
Ctrl End key combination now works in View Scan mode
-
Changed green in Coast Guard four color palette to 65280 on request
Version 2.0.1.95
Features Added
-
Changed width of help panel when closed so as to prevent interference with other controls on lower resolution displays
-
Changed sleep(1) to sleep(100) between stc requests for speeds
-
Changed CSC background to light gray
Fixes
-
Persist floating gate setting beyond session
Version 2.0.1.94
Features Added
-
Added Coating Compensation in Scan Map settings to subtract Coating thickness from gated thickness readings.
-
Added images tab to Analysis (similar to scan) for Stitched ScanMap Images
-
Added Alt F3 function to save image rendered at custom pixels per bin
-
Added Notes Page to Scan
-
Added Notes variable to Report
-
Added Conditions/Results Page to facilitate customization of results by selection
-
Added Velocity override capability to Condiditions/Results to facilitate measurements between gates on bonded surfaces of different velocity.
-
Added IFComp to UT Settings Panel.
Fixes
-
Fixed dates on last two release notes where year was transposed (12 instead of 21)
Version 2.0.1.93
Features Added
-
Added Daylight check-box to brighten AScope (suggested by Guy Thigpen)
-
Hid and disabled operations that are not pertinent on floating gate in Advanced Gate Settings Dialog
-
Added tandem ut (Gladd)
-
Added CoastGuard 4 color palette (Gladd)
-
Added Jog control in Perform Scan Dialog (Gladd)
-
Added interface to STC controller
-
Added Velocity and Acceleration settings for STC controller
-
Added error handling to pause scan for scan recovery using STC controller
-
E-Stop
-
Motion
-
OverCurrent
-
-
Added Color Map dialog by double clicking on color map control.
Fixes
-
Fixed object order where buttons were showing through help panel (Chuck)
-
Fixed hidden Template list if Adding scan, selecting Blank and back on Template
-
Fixed selected Re-gate region missing two cells on the right
-
Fixed UTSettings panel not updating when changes made in AScope
Version 2.0.1.91
This release has so many new features that we decided to post a video overview.
Features Added
-
Added hints over check boxes relating to Heal Data features
-
Added layout tab in utilities
-
Added LayoutSimulation object to manage placement based on settings in record
-
Added capability to select desired layout from combo-box in view and perform
-
Added ability for grid to rotate with CScan
-
Added ability for CScan to rotate
-
Added UT settings panel in UT Setup/Calibrate with advanced settings (requiring PRD update)
-
Modified Amplitude B-Scan palette per user feedback
-
GraphicCal: changed location and description of Clear Dataset button (to avoid confusion) — GraphicCal: Automatically clear and set focus on Edit box (per user feedback)
Fixes
-
Clear Dataset button fixed - variables initialized so that chart resets after ban entry.
-
Fixed images compiled into report that have been rotated by property in layout by saving a copy of the image with -Rotated.ext to use in the compiled report
Version 2.0.1.78
No feature or fix details were provided for this release in the original file.
Version 2.0.1.77
Features Added
-
Added release notes link (bottom right) so we can better communicate added features and fixes.
-
Added Please Wait form while loading large A-Scan Array to inform user better.
-
Added Amplitude B-Scan (horizontal and vertical) in C-Scan control
-
Added ability to use spectrum color instead of gray scale Alt=F6
-
Added feed-back on C-Scan control of re-gate region being operated on.
-
Added ability to lock/unlock cross-hairs on C-Scan control so that a user does not inadvertently load gates from another bin by sweeping over the control. (del key)
-
Added Image of area to statistics dialog
-
Added export to excel to statistics dialog
-
Updated StiSceneViewer (V 1.0.0.7)to match AnalystXR (Filter vertex drawing when in transition to zero reading to prevent average facet color to be RED)
-
Trapped Carriage Width error message from SBC and show warning dialog for clarity.
-
Added ability to Heal data if possible. Requires 3 gate setup echo to echo. When gate 2 is not broken the algorithm attempts to use interface to G1 TOF modified statistically for delta between G1-G2 TOF and IF-G1 TOF. This will help fill in some data when echo to echo is required but signal return is difficult to achieve.
Fixes
-
Attempt to solve ghost image due to timing of windows affects when saving named image
-
Fixed rare issue when pasting selected color-map settings; C-Scan image would be duplicated
-
Fixed run-time format error while exporting csv in scan map dimension mode.
Release Notes
Fixes
-
Changed scaled setting on most forms to FALSE to help when windows uses scaling
-
Fixed translation of scan map when orientation is -1 (90 deg left)
-
Placement of [Change Colormap] button on 3D view page
Version 2/0/1/65
Features Added
-
Added ability to save/load a UT Template for calibration and settings
Version 2.0.1.63
Features Added
-
Added ability to export 3D to STL file
-
Ability to scale gain of A-Scan on re-gate (under Advanced Gate Settings Dialog)
-
Added tri-color palette capability
-
Added ability to copy and paste page in reporting
-
Added "Missing Scan" page and notice of no selection available from existing scan set
-
Added highlighting of pressure below burst for each method in B32G output
-
Added ECScanFile (.ECSF) in set for enhanced gating functions at bin level
-
Added Floating Gate capability
-
Added Amplitude B-Scan in array so that a live display is functional as the crosshairs are moved.
-
Added MergeScans for and function to facilitate the merging of two scans that should otherwise occupy the same envelope with the same settings.
Fixes
-
TriggerType persistence
-
Added condition traps in B31G analysis
-
Fixed minor bug in CommandQueue where Index out of bounds due to fChannel > 0 (this would not happen in normal operation).
-
Filter vertex drawing when in transition to zero reading to prevent average facet color to be RED.
-
Changed mode back to MonitorStream mode after re-gate is complete
-
Small fix for Amplitude B-Scan grayscale Zero value rolling over to black
Version 2.0.1.49
Fixes
-
Fixed but reported from field when using Add Blank Scan causes unresponsive perform scan!
Version 2.0.1.48
Features Added
-
Shortened Live Amplitude B-Scan display to Range instead of Record Length.
Fixes
-
Fixed potential timing problem with tmrReconnect when reset is done. (Unlikely)
Version 2.0.1.46
Fixes
-
Added filter in commands going to Single board computer to prevent corruption of platform.conf file if user fails to select scanner type on touch screen.
-
Apply constraints on AScope gate adjustment to assure values are reasonable.
-
Removed debug ShowMessage that was unintended
-
Fix for report element "line" not responding to drag and drop properly.
Version 2.0.1.42
Features Added
-
Added new Special Functions tab under Utility tab with button [Recover workable UT and Gate Settings]
-
Added live aplitude B-Scan display (optional with check box) while performing scan
-
Added Manual
Fixes
-
Added an event to facilitate proper field validation while changing units
-
Trap range settings and frequency settings that are invalid
-
Fix for metric C-Scan Scale
-
Fixed small memory leak with fds.free (missing)
-
Added test for empty scan set when leaving General page